CA190 TILTIMA

SPECIFICATION:

Color : Black, Blue, Beige, Grey, Burgundy
Control Type : Hand Control, 2 x Foot Controls
Compare
Categories: ,

Description

CA190 “TILTIMA” 1 Section Tilt Table (2 Motors)

Please select a Colour:

Blue / Black / Grey / Beige / Burgundy

Please select a `Table` Width & Control Type:

1) With 1 x Hand Control (4 Buttons) -> Nominal Unit Price

2) With 2 x Foot Controls (2 Switches Each) -> Add (+) USD $120

• 1 x Motorized Actuator for Hi/Lo Adj.

• 1 x Motorized Actuator for Tilt Adj.

• Available Controllers: Hand Control (Highly Recommend)

• Available Colours (Please select a Colour):

• Black • Grey • Blue • Beige • Burgundy

• Columned Bracket Frame for Added Stability during Hi / Lo Adj.

• 4 x 5″ inch Castor with Individual Brake & Swivel Lock

• Emergency Disengagement Lever disengages motor lock when utility power is unavailable. The emergency disengagement lever utilises Twin Gas Struts for smooth sliding from Vertical to Horizontal position.

• Maximum Load Capacity of 225 kgs / 496 lbs

• Warranty Period (Years):

• 1 yr on Mechanical Parts

• 2 yrs on Electronics

• 3 yrs on Frame

• 100~240VAC (Universal Voltage)

• Plug Type: US Plug

CA190 Tiltima® is the Ultima of Tilt Tables for diagnosis of syncope and/or dysautonomia. In terms of its comfort rating, mechanical stability and operational movement, it is one of the best. The two adjustable patient’s foot platform (Foot Paddle) can be tilted to a positive angle of 20º degree.

The CA190 Tiltima® is equipped with the following accessories in the package:

a) Chest Strap * 1

b) Thigh Straps * 2

c) Calf Straps * 2

d) Working Table * 1

All 4 corners of the CA190 Tiltima® are supported by a 5” inch castor with Swivel Lock and Brake. The Frame Construction is made with Steel Tubes of (a) 6 * 3cm and (b) 7 * 3cm Dimensions and by the thickness of 2mm.

For absolute safety requirement, the CA190 Tiltima® is equipped with a “1-PULL EMERGENCY HANDLE” at the back of table.

When in an emergency situation where no utility power is available, the emergency handle can be pulled to allow the table top to be moved back from vertical to horizontal position and the patient can then be unstrapped and transferred to normal patient’s bed.

In any given case of loss of utility power, just pull on the RED EMERGENCY HANDLE at the back of table to disengage the Motorized Actuator (otherwise locked) to allow the patient to be unstrapped and lifted off the table.

CA190 Tiltima® is controlled by a (4 Buttons) Hand Control:

• 1st Motorized Actuator: Height Adjustment (55~90cm)

• 2nd Motorized Actuator: Tilt Angle Adjustment (0º~90º)

In any given case of loss of utility power, just pull on the RED EMERGENCY HANDLE at the back of table to disengage the Motorized Actuator (otherwise locked) to allow the patient to be unstrapped and lifted off the table.

CA190 Tiltima® is controlled by a (4 Buttons) Hand Control:

• 1st Motorized Actuator: Height Adjustment (55~90cm)

• 2nd Motorized Actuator: Tilt Angle Adjustment (0º~90º)

TECHNICAL SPECIFICATIONS:

Minimum Height: 550mm / 21.65” inch

Maximum Height: 900mm / 35.43” inch

Top Height at 90º: 2100mm / 82.67” inch

Table Top Width: 650mm / 25.59” inch

Total Length: 1900mm / 74.80” inch

Tilt Angle: 0º to 90º

Lift Mechanism: Electric

Breathing Hole/Plug: N/A

Castors w/h Swivel Lock & Brake: 4

Weight Rating (Max. Load): 225kgs / 496lbs

Net Weight: 89.5 kgs

Gross Weight: 104.8 kgs

Package Dimension: 209 x 86 x 59 cm

Container Load Capacity

• 20ft: 21 tables

• 40ft: 42 tables

• 40ft HQ: 56 tables

Electrical Data

Control Box Input Voltage & Rating: 100~240VAC, 50/60Hz, 2A

Control Box Output Voltage: DC 32V, 80VA

Actuator Input Voltage: DC 24V

Duty cycle: Max. 10% 2min. ON / 18min. OFF

Max. Load: Push 8000N

Max. Current: Max. 6A

CERTIFIED TO AAMI / CSA / IEC / EN STD

AAMI ES 60601-1, CSA-C22.2 NO. 60601-1

IEC 60601-1, EN 60601-1

The electrical components used are approved by IEC 60601-1

Reviews

There are no reviews yet.

Be the first to review “CA190 TILTIMA”